Electronic Metering Pumps
Series C, C+, A+, E, E-DC, E+ & HV
Installation
Operation
Maintenance
Instruction
READ ALL WARNINGS CAREFULLY
BEFORE INSTALLING
Vista de página 0
1 2 3 4 5 6 ... 15 16

Resumo do Conteúdo

Página 1 - Electronic Metering Pumps

Electronic Metering Pumps Series C, C+, A+, E, E-DC, E+ & HV Installation Operation Maintenance Instruction READ ALL WARNINGS CAREFULLY BE

Página 2 - TABLE OF CONTENTS

10 5.5 Operation By External Input Signals (Options): The pump can be controlled by three types of input signals. All are fully isolated from AC inp

Página 3 - READ ALL INSTRUCTIONS

11 For the 4-20 mA input to have any effect on the pump output rate, the AUTO/OFF/MANUAL switch must be in the AUTO position. The 4-20 mA input signa

Página 4 - 2.0 UNPACKING THE PUMP

12 Depressurize the system and disconnect tubing or piping from the pump. Remove the four pump head screws and then remove the pump head assembly.

Página 5 - 4.0 INSTALLATION

13 7.0 TROUBLESHOOTING Problem Probable Cause Remedy Failure to Pump 1. Leak in suction side of pump 2. Valve seats not sealing 3. Low setting o

Página 6 - 4.2 Piping

14 Leakage at Tubing Connections 1. Worn tube ends 2. Chemical attack 1. Cut off end of tubing approximately one inch (2.5cm) and reconnect 2. C

Página 7 - Figure 6

15 8.0 POLICIES AND PROCEDURES 8.1 Manufacturers Product Warranty The manufacturer warrants its equipment of its manufacture to be free of defects in

Página 8 - 5.0 START UP AND OPERATION

16 L9408900-000 Rev E USA Pulsafeeder, Inc. 27101 Airport Rd.

Página 9 - 5.4 Control Panel Symbols

2 TABLE OF CONTENTS 1.0 SAFETY INSTRUCTIONS ...

Página 10

3 1.0 SAFETY INSTRUCTIONS When using chemical feed pumps, basic safety precautions should always be followed to reduce risk of fire, electric shoc

Página 11 - 6.0 MAINTENANCE

4 An air bleed valve is available for most models with tubing connections. Air purges should be performed when the pump-chamber contains no fluid at

Página 12 - 6.4 Valve Replacement

5 3.0 INTRODUCTION These installation, operation and maintenance instructions cover your electronic metering pump. Refer to the pump data label to d

Página 13 - 7.0 TROUBLESHOOTING

6 USE AN ANTI-SIPHON VALVE IN THE DISCHARGE LINE whenever the fluid pressure in the discharge line is below atmospheric pressure. This can occur if

Página 14

7 A flooded suction (tank liquid level always at a higher elevation than the pump) is recommended when pumping solutions such as sodium hypochlorite

Página 15 - 8.0 POLICIES AND PROCEDURES

8 5.0 START UP AND OPERATION 5.1 Power All metering pumps are available in 115 and 230 volts at 50/60 Hertz, single phase. In addition, certain mode

Página 16

9 5.3.2 Stroke Length Adjustment Stroke length can be controlled within 0 to 100% of the diaphragm displacement. It should be controlled within 20 to