MANUAL ADDENDUM PULSAtron SERIES ET
The PULSAtron Series ‘ET’ pump is slightly different then the ‘E+’ pumps with an external pace option. An
externally paced ‘E+’ will actuate the solenoid once per water meter contact, the series ‘ET’ will run at
maximum stroke rate for a preset time every one(1) or ten(10) water meter contacts depending on the mode
switch setting. The meter input is specifically for a dry contact water meter. The water meter output is an
isolated dry contact output that duplicates the state of the water meter allowing a single water meter to run
more than one pump. The mode selection switch has six positions, they are:
1. Standby: The pump will remain off in this state, just as in any other pump. The water meter input
and outputs are disabled in this mode.
2. On: The pump will work like a standard “E+” Series pump in this mode. The water meter input and
outputs are disabled. The percent of scale knob adjusts the frequency that the pump strokes.
3. 200SEC/1CT: The pump will run for a set time for every water meter contact. The percent of scale
knob is used to select the run time from 2-seconds (1%) to 200-seconds (100%).
4. 200SEC/10CT: The pump will run for a set time for every 10-water meter contacts. The percent of
scale knob is used to select the run time from 2-seconds (1%) to 200-seconds (100%).
5. 20MIN/1CT: The pump will run for a set time for every water meter contact The percent of scale
knob is used to select the run time from 0.2-minutes (1%) to 20-minutes (100%).
6. 20MIN/10CT: The pump will run for a set time for every 10-water meter contacts. The percent of
scale knob is used to select the run time from 0.2-minutes (1%) to 20-minutes (100%).
NOTE: In modes 3 thru 6 the water meter output will mirror the state of the water meter input and
the pump will run at maximum stroke rate for the selected time.
L9407300-000 Revision 20-A-9
Vista de página 0
1 2 3 4 5 6 ... 16 17

Resumo do Conteúdo

Página 1

MANUAL ADDENDUM PULSAtron SERIES ET The PULSAtron Series ‘ET’ pump is slightly different then the ‘E+’ pumps with an external pace option. An exte

Página 2 - Electronic Metering Pumps

9 5.3.2 Stroke Length Adjustment Stroke length can be controlled within 0 to 100% of the diaphragm displacement. It should be controlled within 20 to

Página 3 - TABLE OF CONTENTS

10 5.5 Operation By External Input Signals (Options): The pump can be controlled by three types of input signals. All are fully isolated from AC inp

Página 4 - READ ALL INSTRUCTIONS

11 For the 4-20 mA input to have any effect on the pump output rate, the AUTO/OFF/MANUAL switch must be in the AUTO position. The 4-20 mA input signa

Página 5 - Figure 1

12 Depressurize the system and disconnect tubing or piping from the pump. Remove the four pump head screws and then remove the pump head assembly.

Página 6 - 4.0 INSTALLATION

13 7.0 TROUBLESHOOTING Problem Probable Cause Remedy Failure to Pump 1. Leak in suction side of pump 2. Valve seats not sealing 3. Low setting o

Página 7 - 4.2 Piping

14 Leakage at Tubing Connections 1. Worn tube ends 2. Chemical attack 1. Cut off end of tubing approximately one inch (2.5cm) and reconnect 2. C

Página 8 - Figure 6

15 8.0 POLICIES AND PROCEDURES 8.1 Manufacturers Product Warranty The manufacturer warrants its equipment of its manufacture to be free of defects in

Página 9 - 5.0 START UP AND OPERATION

16 L9408900-000 Rev E USA Pulsafeeder, Inc. 27101 Airport Rd.

Página 10 - 5.4 Control Panel Symbols

Electronic Metering Pumps Series C, C+, A+, E, E-DC, E+ & HV Installation Operation Maintenance Instruction READ ALL WARNINGS CAREFULLY BE

Página 11

2 TABLE OF CONTENTS 1.0 SAFETY INSTRUCTIONS ...

Página 12 - 6.0 MAINTENANCE

3 1.0 SAFETY INSTRUCTIONS When using chemical feed pumps, basic safety precautions should always be followed to reduce risk of fire, electric shoc

Página 13 - 6.4 Valve Replacement

4 An air bleed valve is available for most models with tubing connections. Air purges should be performed when the pump-chamber contains no fluid at

Página 14 - 7.0 TROUBLESHOOTING

5 3.0 INTRODUCTION These installation, operation and maintenance instructions cover your electronic metering pump. Refer to the pump data label to d

Página 15

6 USE AN ANTI-SIPHON VALVE IN THE DISCHARGE LINE whenever the fluid pressure in the discharge line is below atmospheric pressure. This can occur if

Página 16 - 8.0 POLICIES AND PROCEDURES

7 A flooded suction (tank liquid level always at a higher elevation than the pump) is recommended when pumping solutions such as sodium hypochlorite

Página 17

8 5.0 START UP AND OPERATION 5.1 Power All metering pumps are available in 115 and 230 volts at 50/60 Hertz, single phase. In addition, certain mode